Rubin TEMPERATURE CONTROL

Heating/cooling control system designed for server rooms and data centers and providing intelligent climate control by a combination of a number of different procedures. 

We economically combine the benefits of air-conditioning and ventilation systems while using an alternative method. We have developed a unit that monitors outdoor and indoor temperatures, the factory parameters of air conditioning and ventilation and controls equipment to reach optimum room temperature and economical operation.

 

MG_9056gr4

 

We recommend this service to…

Companies and providers where the datacenter has a key function in the process.

Service features:

Careful planning and coordinated work of various specialties are needed to design and successfully operate the system. In addition to providing the appropriate hardware equipment, we design the control unit, visit the location and assess it from a mechanical engineering aspect, and then design and implement the system.

abra7System benefits:

Energy efficiency. Optimum and energy efficient temperature control of computer rooms using a flexible software and a carefully designed modular hardware.
Exceptional system security.
High level noise and interference protection.
Lower maintenance and investment costs. During maintenance the available data allows for fault prevention. The maintenance period is determined based on the measured and the reduced operating period.
The system is flexible to expand.

 

Rubin Hardware equipments

We have over a decade of experience in the development and manufacturing of infrastructure management equipment and software.  This multi-faceted knowledge allows for the deployment of distributed systems where savings on labor time, operating and energy costs result in fast return on investment and increased reliability of the managed system even in the short run.

System success is provided through a wide variety of equipment. The appropriate temperature control equipment is always selected for the specific site and expected functionality.

 

coolrubiconsmecounter

 

 

 

Reliability

We have over a decade of experience in the development and manufacturing of infrastructure management equipment and software.  This multi-faceted knowledge allows for the deployment of distributed systems where savings on labor time, operating and energy costs result in fast return on investment and increase the reliability of the managed system even in the short run.

The devices of Rubin Inc. operate 24/7 at over 2,500 points of the national management system of Magyar Telekom Plc. The average annual fault rate is below 1% and the ratio of own faults is below 0.1%.

 

Support

We have contracted partners to carry out first-line support tasks. Based on the specific contracts, second-line tasks may include value added services like 12-hour or 24-hour “hotline” or “replacement device for the duration of repair”.

 

Operating modes

Based on its configuration settings, every single product of Rubin Inc. can manage and control connected devices even when they are offline. The operating advantages of the system are visible when online, and the relevant SCADA system (PNM) can significantly cut down operating costs with the organization, processing, evaluation and single system display of the collected data.

 

Data transfer options

In terms of physical lines the system is rather heterogeneous because we use the data transfer channel most suitable for each specific location:

  •     RS232 and RS485 asynchronous physical lines with speeds between 1,200–115,000 bps
  •     10BaseT Ethernet transfer,
  •     HDLC and E1/T1 protocol for communication with telecommunication devices,
  •     v.23 voice frequency modem connection,
  •     v.11 synchronous data transfer,
  •     GPRS modem connection with TCP/IP protocol,
  •     PPP, SNMP protocol over IP line,
  •     XML RPC, HTTP(S), SSH protocols over TCP/IP lines.

 

Router

Operating safety of the system is primarily affected by the backbone network; disconnection means an ongoing issue in a tree system. One typical issue used to be related to the high number of devices. In order to minimize this issue, we separated the system into smaller pieces by adding our proprietary routers to create a system with redundant routes that we still use. Our routers are Linux based industrial computers with a maximum of 32 ports towards the devices and with IP connection to the center. The key to this solution is the IP network with redundant transfer routes and a remotely managed (SNMP) intelligent device to create flexibility and increased reliability.

Our products can be updated remotely just as configuration data can be accessed and set up remotely.

Cost-effective, modular, free-to-program structure for smaller systems.

 

Rubin COOL Case Study

Demand for comfort has increased at homes and industrial facilities over the past decades. This inevitably led to the need of climate control almost everywhere.

moreinfo

 

 

Rubin RUBICON Biatorbágy Case Study

The project is designed to create a control system using the equipment developed by Rubin that controls the cooling of the rooms in the buildings to ensure the most energy efficient operation via active cooling or, if possible, ventilation.

moreinfo